Measuring functions

The measuring tool offers the following measuring functions:

  • Measurement of alternating current
  • Measurement of resistance
  • Continuity test
  • Measurement of alternating voltage
  • Measurement of direct voltage

  • Use for measurements always the proper input terminals, switch position and measuring range.
  • Check the test leads for continuity before use. Do not use if the readings are high or noisy.
  • Keep your fingers behind the finger guards while using the test leads.
  1. Turn the rotary switch (3) to the position in the figure.

When Using Test Leads:

  1. Connect test leads (10) and (9) as shown in the figure.
  2. Contact the test points with the test probes.
  3. The measured value is shown on the display (1).

When Using the Measuring Clamp:

  1. Push the lever (2) to open the measuring clamp (5).
  2. Enclose the cable to be measured with the measuring clamp (5) and close the measuring clamp by releasing the lever (2).
  3. The measured value is shown on the display (1).

  • Keep your fingers behind the finger guard when using the measuring clamp.
  • Do not take any measurements if the open-circuit potential to earth is more than 600 V.
  1. Take the measurement with the measuring clamp see Measuring functions.

  1. Take the measurement with the test leads see Measuring Process.

  1. Take the measurement with the test leads see Measuring Process.
  2. If the continuity test is successful, a continuous tone is output.

  1. Take the measurement with the test leads see Measuring Process.

  1. Take the measurement with the test leads see Measuring Process.