Starting Operation

To switch on the power tool, press the on/off switch (7) for approx. one second until an audio signal sounds. The LED status indicator (3) flashes, indicating that the power tool is now in standby mode. Press the trigger switch (8) once to open the blade (1). The LED status indicator (3) lights up continuously and the power tool is ready for use.

To switch off the power tool, press and hold the on/off switch (7) for one second.

Note: Only switch the power tool off when the blade (1) is closed.

The power tool switches off automatically after 180 seconds. The LED status indicator (3) goes out. Press the on/off switch (7) again to switch it back on. When the blade (1) is open, it moves briefly, signalling that the power tool is ready for use again.

When the blade (1) is open, the power tool switches to standby mode after 60 seconds. The LED status indicator (3) flashes. To activate the power tool, press the trigger switch (8).

As soon as the power tool is ready for use, press the trigger switch (8) to activate the blade (1). Press and hold the trigger switch (8) until the blade (1) is fully closed. The blade (1) remains in the closed position. To open the blade (1) back up, press on the trigger switch (8) again.

The LED status indicator (3) is used to indicate the state of the power tool.

LED status indicator (3)

State

Corrective measures

Lights up permanently

Power tool ready for cutting

Slowly flashing

Standby

Quickly flashing

Battery or tool error

Charge the battery, allow the power tool to cool down or remove the battery and reinsert it

The worklight is activated as soon as the trigger switch (8) is pressed. It lights up for approx. 10 seconds.

The blade opening can be set to 20 mm or 32 mm. To do this, press the on/off switch (7) twice each in quick succession. One beep sounds for a blade opening of 20 mm; a double beep sounds for a blade opening of 32 mm. When the blade (1) is opened again, the changed blade opening becomes active. If the blade (1) was opened during adjustment, it must first be closed for the new blade opening to become active.