Technical data

Voltage tester

GVD 1000-17

Article number

‎3 601 K77 0..‎

Measuring ranges

90–1000 V AC/
24–1000 V AC

Frequency range

50/60 Hz

General

Operating temperature

–10 °C to +50 °C

Storage temperature

–40 °C to +70 °C

Relative air humidity max.

80 % (non-condensing)

Max. altitude

2000 m

Pollution degree according to IEC 61010-1A)

2

Automatic switch-off after approx.

5 min

WeightB)

0.05 kg

Protection rating

IP 67 (protected against dust and temporary submersion)

Safety class

CAT IV 1000 VC)

Dimensions (L x W x H)

161.5 × 28 ×
33 mm

Batteries

2 × 1.5 V LR03 (AAA)

A)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

B)

Weight without batteries

C)