Technical data

Digital Multimeter

GDM 600-15

Article number

‎3 601 K77 3..‎

Measuring range for voltage

600 V AC/DC

Measuring range for current

10 A AC/DC

Measuring range for frequency

50 kHz AC V
2 kHz AC A

Measuring range for resistance

40 MΩ

Measuring range for capacitance

1000 µF

Continuity testing

True RMS (root mean square measurement)

General

Operating temperature

–10 °C to +50 °C

Storage temperatureA)

–40 °C to +70 °C

Relative air humidity max.

90 %

Max. altitude

2000 m

Pollution degree according to IEC 61010-1B)

2

Automatic switch-off after approx.

20 min

WeightC)

0.37 kg

Protection rating

IP 65

Safety class

CAT III 600 VD)

Dimensions

78.3 × 59.3 × 177.3 mm

Test leads MS 90

Safety class with protective caps

CAT III 1000 VD)

CAT IV 600 VE)

Safety class without protective caps

CAT II 1000 VF)

Fuse

Type

F

Rated voltage

600 V

Rated current

10 A

Switching capacity

10 kA

Dimensions

6.3 × 32 mm

Non-rechargeable batteries

2 × 1.5 V LR06 (AA)

Battery pack (accessory)

Li-ion

Recommended ambient temperature during charging

+10 °C to +35 °C

Recommended ambient temperature during operation and during storage

–10 °C to +45 °C

Type

BA 3.7V 1.0Ah A

Article number

‎1 607 A35 0N8‎

USB charging connection

Type-C®

Recommended USB Type-C® cableG)

‎1 600 A01 6A8‎

Rated voltage

3.7 V

Capacitance

1.0 Ah

Number of battery cells

1

Power supply (accessory)

Output voltage

5.0 V

Output current

500 mA

Recommended power supplyH)

‎2 609 120 713 (EU)‎

‎2 609 120 718 (UK)‎

‎1 600 A01 3A0 (ARG)‎

‎1 600 A01 3A1 (MEX)‎

‎1 600 A01 3A2 (BRL)‎

A)

Without batteries and/or rechargeable batteries

B)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

C)

Weight without batteries

D)

MEASUREMENT CATEGORY III is applicable to test and measuring circuits connected to the distribution part of the building's lowvoltage mains installation.

E)

MEASUREMENT CATEGORY IV is applicable to test and measuring circuits connected to the supply point of the building's low-voltage mains installation.

F)

MEASUREMENT CATEGORY II is applicable to test and measuring circuits connected directly to 1768 utilization points (socket outlets and similar points) of the low-voltage mains installation.

G)

USB Type-C® and USB-C® are trademarks of USB Implementers Forum.

H)

For additional technical data, visit: https://www.bosch-professional.com/ecodesign