Wet vacuuming

Note: The requirements for the degree of penetration (dust class M) have only been verified for dry extraction.

Steps to Take before Wet Vacuuming

  • Remove the disposal bag (25) or dust bag if necessary.

Note: Use a wet filter bag (accessory), which separates liquid from solids, to make disposal easier when vacuuming water-solid mixtures.

  • Place the rubber lip (28) into the floor nozzle (30).
  • Switch off the automatic filter cleaning (AFC).

Vacuuming up liquids

To switch on the dust extractor, set the mode selector switch (7) to the “extraction” symbol.

The dust extractor is equipped with fill level sensors (37). The dust extractor shuts down if the maximum fill level has been reached. Set the mode selector switch (7) to the "switch off" symbol.

Note: When extracting non-conductive liquids (e.g. drilling emulsion, oils and fats), the dust extractor will not switch off when the container is full. The fill level must be constantly monitored and the container emptied in good time.

If the acoustic warning signal sounds during wet extraction, the operating reliability of the dust extractor is not affected. No measures to rectify the fault are necessary.

  • To switch off the dust extractor, set the mode selector switch (7) to the "switch off" symbol.
  • To transport the dust extractor, screw the sealing plug (2) onto the hose adapter (3).
  • Empty the container (1).

To prevent mould growth after wet extraction:

  • Remove the flat-pleated filter (26) and leave this to dry thoroughly.
  • Remove the top part of the dust extractor (12), open the filter cover (36) and leave both elements to dry thoroughly.